Beam Load Cell
Brand | HBM |
Model | Z6FC3 |
Type | Bending Beam |
Capacity | 500 Kg |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Portable Weighbridge |
Features | Hermetically sealed, Low Profile |
Load Cell Certifications | ATEX, OIML |
Output Sensitivity(FS) | 2.0 +/- 0.002 mV/V |
Combined Error | <+/- 0.030% FS |
Creep Error (30 minutes) | <+/-0.030 %FS |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | +/-0.002 FS/DegC |
Temperature Effect on Output | +/-0.001 FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -20 to +70 Deg C |
Cable Length | 1-20 meter |
We are actively engaged in manufacturing and supplying quality high amount of Beam Load Cells.
Features
- Hermetically sealed to IP68
- Specially designed for harsh environment
- Low profile platforms
- Pallet truck weighing
- Harsh environment weighing
- Food industry weighing
Single Point Load Cell
Product Brochure
Brand | Flintec |
Model | PC22 |
Capacity | 5 KG- 40 KG |
Material | Aluminum |
Ingress Protection | IP67 |
Application | Bench Scale |
Features | Hermetically Sealed |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Creep Error (30 minutes) | +/- 0.06 |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Input Resistance | 413 +/- 20 Ohms |
Output Resistance | 350+/-25 Ohms |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -20 to +70 Deg C |
S type Load Cell
Product Brochure
Brand | Flintec |
Model | UB1 |
Capacity | 1020- 5099 Kg |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Crane Scale |
Features | Current Calibrated |
Load Cell Certifications | ATEX, OIML |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | +/-0.050% FS |
Creep Error (30 minutes) | +/-0.060% FS |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | +/- 0.020 % FS/DegC |
Temperature Effect on Output | +/- 0.040 % FS/DegC |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 200% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 1100 +/- 50 Ohm |
Output Resistance | 1000 +/- 2 Ohm |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Compression Loadcell
Product Brochure
Brand | ADI |
Model | 90210 |
Capacity | 5- 100 Ton |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Hopper Scales |
Features | Hermetically Sealed |
Load Cell Certifications | OIML |
Output Sensitivity(FS) | 2.0 +/-0.1 mV/V |
Creep Error (30 minutes) | <= +/- 0.03 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0020 |
Temperature Effect on Output | <= +/- 0.0015 |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 25V DC |
Input Resistance | 450 +/- 2 Ohm |
Output Resistance | 480 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperature Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 20 Meter |
We provide premium quality Compression Loadcell with the top class standards and performance
Features:
- Simple Installation
- ATEX and High Temperature versions available
- Stainless Steel Load Sensor
- Self-Centering column design with anti-rotation pin
- Environmental protection IP68/IP69K
- Tank Weighing
Button Load Cell
Product Brochure
Brand | ADI |
Model | 90610-M |
Capacity | 200- 3000 Kg |
Material | Stainless Steel |
Ingress Protection | IP65 |
Application | Compression Testing |
Features | Test Bench & Automation |
Load Cell Certifications | OIML |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Creep Error (30 minutes) | <= +/- 0.03%FS |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.005%FS/DegC |
Temperature Effect on Output | <= +/- 0.005%FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 250% FS |
Recommended Excitation Voltage | 10 to 12V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 390 +/- 10 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 1- 20 meter |
We supply supreme quality Button Load Cell with the most superior standards and performance available.
Specifications:
- Silo, Tank, Vessel Weighing
- Low Profile, extremely compact loading assembly
- Allows Vessel expansion & contraction
- Integral Jacking Facility
- 1000 division accuracy
- Environmental Protection IP68/ IP69K
- Allowance for Angular Mis-alignment
S- Type Loadcell
Product Brochure
Brand | Thames |
Model | T60 |
Capacity | 50 Kg- 6 Ton |
Material | Stainless Steel |
Ingress Protection | IP67 |
Application | Tensile Testing Machine |
Features | High Accuracy & Precision, Corrosion Resistant |
Load Cell Certifications | NTEP, ATEX, OIML |
Output Sensitivity(FS) | 2.0 +/- 0.2 mV/V |
Combined Error | <= +/- 0.017 |
Creep Error (30 minutes) | <= +/- 0.016 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.002 |
Temperature Effect on Output | <= +/- 0.0012 |
Zero balance | +/- 2.0% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 10 to 12V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 400 +/- 20 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -30 to +70 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 6 Meter |
We supply finest quality S-type loadcell with the most supreme standards and performance available
Features:
- Simple low cost installation
- Corrosion Resistant
- High quality steel load sensor
- Fully potted & sealed to IP67
- High quality tool steel construction
- Industry standard configuration
- Tension & Compression testing
- Tank & Vessel Weighing
- Bag filling machines
- Concrete batching equipments & conveyors
Double Ended Shear Beam Load Cell
Model | Flintec DSB7 |
Type | Double Ended Shear Beam |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Hopper Scales |
Features | Hermetically sealed |
Output Sensitivity(FS) | 2.0 +/- 0.002 mV/V |
Creep Error (30 minutes) | +/- 0.03% FS |
Temperature Effect on Zero | +/-0.02% FS/DegC |
Temperature Effect on Output | +/-0.01% FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Double Ended Beam Load Cell
Product Brochure
Model | Flintec SB8 |
Type | Double Ended Shear Beam |
Capacity | 10 Kg- 500 Kg |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Pallet Truck Scales |
Features | High Accuracy & Precision |
Load Cell Certifications | NTEP, OIML |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | <= +/- 0.0200 |
Creep Error (30 minutes) | <= +/- 0.0166 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0140 |
Temperature Effect on Output | <= +/- 0.0100 |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 200% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 380 +/- 10 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 3 Meter |
We deal in good quality Double Ended Beam Load Cell with the most premium standards and performance
Features:
- Batching, Blending & Mixing Systems
- Excellent Performance for High Capacity Loading
- Excellent Combined Error & Repeatability
- Level & Inventory Monitoring
- Tank, Bin & Silo Weighing
Single Ended Beam Load Cell
Product Brochure
Brand | Thames |
Model | T85 |
Type | Single Ended Shear Beam |
Capacity | 300 Kg- 10 Ton |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Pallet Truck Scales |
Features | High Accuracy & Precision |
Load Cell Certifications | NTEP, OIML |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | <= +/- 0.017 |
Creep Error (30 minutes) | <= +/- 0.016 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.002 |
Temperature Effect on Output | <= +/- 0.0012 |
Zero balance | +/- 2.0% FS |
Maximum Safe Overload | 200% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 400 +/- 20 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -30 to +70 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 12 Meter |
We provide premium quality Single Ended Beam Load Cell with the most superior standards and performance
Application:
- Low Profile Floor Scales
- Tank, Hopper & Bag Weighing
- Force, Tension Measurement
- Industrial Automation
- Pallet Scale
Single Point Load Cell
Product Brochure
Brand | Flintec |
Model | PC46 |
Capacity | 50- 250 Kg |
Material | Aluminum |
Ingress Protection | IP67 |
Application | Platform Scale |
Features | Low Profile |
Load Cell Certifications | OIML, ATEX |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | <= +/- 0.0200 |
Creep Error (30 minutes) | <= +/- 0.0166 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0187 |
Temperature Effect on Output | <= +/- 0.0100 |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 413 +/- 20 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 3 Meter |
We provide finest quality Single Point Load Cell with most premium standards and performance
Specifications:
- Packaging & Grading Machines
- Bench Scales
- Bottle filling machinery
- Bag filling equipment
- Environmentally Sealed by Potting
- Stainless Steel Construction
- Wide range of capacities
- High Accuracy
- OIML, NTEP, ATEX, FM Certified
S40A - S Type Load Cell - HBM
Model | S40A |
Capacity | 50 kg to 5 ton |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Tensile Testing Machine |
Load Cell Certifications | OIML |
Output Sensitivity(FS) | 2.0 +/- 0.2 mV/V |